Products info
| Product names | Chemical anchor[2008-09-04] |
|---|---|
| Trademark | |
| Model | M12 |
| Standard | |
| List Price |
Detailed Description
- Specifications:
- The chemical anchor capsule(chemical bolt) is an epoxy-acrylic resin, styrene free, sands, and a benzoyl peroxide catalyst. They are non-expansive, stress-free anchors, and can be installed at closer center and edge spacings without reducing concrete load bearing capacity.
Installation parameters:
Chemical Anchor Capsule
Chemical Anchor Stub: Steel 5. 8 / stainless steel 316
Drill hole diameter
Depth of drill hole
Maximum Anchor thickness
Description
L [mm]
D [mm]
H [mm]
H [mm]
M10
130
12
90
20
M12
160
14
110
25
M16
190
18
125
35
M20
260
22
170
65
M24
300
28
210
65
M30
380
35
280
65
Average destroy load of individual anchor bolts: Unit: KN
Chemical anchor
M10
M12
M16
M20
M24
Tension
C 30 concrete
Steel 5. 8
32.2
45.8
71.8
128.4
188.6
Stainless steel 316
36.8
58.8
76.9
137.7
196.6
Shear
C 30 concrete
Steel 5. 8
19.7
29.8
48.0
78.8
111.6
Stainless steel 316
27.4
36.6
63.7
100.8
119.6
Individual design load of anchor bolts: Unit: KN
Chemical anchor
M10
M12
M16
M20
M24
Tension
C 30 concrete
Steel 5. 8
10.9
16.2
23.1
42.7
59.6
Stainless steel 316
10.9
16.2
23.1
42.7
59.6
Shear
C 30 concrete
Steel 5. 8
12.1
17.7
33.0
51.4
74.2
Stainless steel 316
13.1
19.0
35.3
55.2
44.2
Spacing and Edge distance
M10
M12
M16
M20
M24
Effective anchorage depth
hef
[mm]
90
110
125
170
210
Characteristic spacing
scr,N
[mm]
220
270
310
420
520
Characteristic edge distance
ccr,N
[mm]
110
135
155
210
260
Minimum spacing
smin
[mm]
90
110
125
170
210
Minimum edge distance
cmin
[mm]
45
55
65
85
105
Min. thickness of concrete slab
hmin
[mm]
140
160
175
220
260
Installation:
1. Prefix drill hole using drill, maintaining the specified drill hole depth and drill hole diameter
2. Remove drill dust completely
3. Insert the right glass resin capsule
4. Turn stud into drill hole using drill attachment. Stop when the setting depth specified reaches the surface
5. The anchor is correctly fixed when the setting depth specified flushes with the drill hole surface and excess mortar is discharged from the hole. If excess mortar fails to come out of the drill hole, the anchor stud must be removed immediately
6. An additional capsule must be inserted along side to the previous capsule and the same procedure repeated to fix the anchor however at all times. Excess mortar shall be discharged from the hole to indicate proper fixing
7. Connect fixture at the end of the curing and tighten with nut the washer. After the appropriate setting time tighten the fixing and apply the work load.
- [ Keywords: anchor , rod , chemical anchor , adhesive , capsule ]
- [ Similar Keywords: Chemical Anchor , Chemical Anchoring ]
Contact Info

- - Company Name: Hangzhou Yuanda Adhesive Material Co., Ltd.
- - Company Address : 1407Room No. 271 Hushu South Road
- - City/Town: Hangzhou
- - Province/State: Zhejiang
- - Country/Region: China
- - Zipcode: 310015
- - Telephone: 86-571-88392014
- - Fax: 86-571-88390646
- - Full Name (Department): Guangyue Yan ()
- - WebSite: Click Here To Visit Our Website
- Contact Us